Posted on 20 Oct, 2022, in Uncategorized
Steps needed to convert a Standalone or SZ/ZD managed AP to Unleashed Firmware
Posted on 20 Oct, 2022, in Uncategorized
How to deal with Recover.Me when the client only sees this on the WiFi connections.
The Configure.Me or the current SSID disappears
Posted on 14 Oct, 2022, in Uncategorized
This article walks you through installation of DHCP server and configuring it to provide option43 setting to Ruckus APs. Once the APs retrieve a DHCP IP with option43 string they will discover ZD or SCG for management.
Posted on 14 Oct, 2022, in Uncategorized
Redirect URL format used in external WISPr for HTTP/HTTPS POST
Posted on 14 Oct, 2022, in Uncategorized
How to register an account on Ruckus Support portal
Posted on 11 Oct, 2022, in Uncategorized
Due to the design of Off-Line and Line-Interactive UPSs, when the AC input source is cut over to the battery source, a delay of 6-8ms in the supply of power to the connected device will occur. The RPS22 power supply treats this delay as an AC dropout condition, and this results in a soft reset. The RPS21 power supplies are not impacted by this condition.
Posted on 11 Oct, 2022, in Uncategorized
ICX may behave abnormal once the system uptime is 1242 days or more.
Posted on 07 Oct, 2022, in Uncategorized
When switch is downgraded from 8095x to 8090x using ZTP, switch goes into a boot loop with error messages:
0:cmicx_sbusdma_curr_op_details: DMU_SEL = 0x00010840, DMU_STAT = 0x00000001
0:cmicx_sbusdma_curr_op_details: CMIC_CMCx_SHARED_AXI_STAT: 0x00000000
0:_cmicx_sbusdma_reg_complete: SOURCE_TRUNK_MAP_MODBASE.ipipe0 failed(ERR)
0:cmicx_sbusdma_error_details: Error while copying SBUSDMA data from Host Memory.
0:_bcm_modules_init: bcm_init failed in commom
fdry_system_init: BCM driver layer init failed: Operation failed
ERROR: SOC unit 0 system_init failed
********** BCM SDK init FAILED *************
Posted on 07 Oct, 2022, in Uncategorized
Due to the design of Off-Line and Line-Interactive UPSs, when the AC input source is cut over to the battery source, a delay of 6-8ms in the supply of power to the connected device will occur. The RPS22 power supply treats this delay as an AC dropout condition, and this results in a soft reset. The RPS21 power supplies are not impacted by this condition.
Posted on 07 Oct, 2022, in Uncategorized
Due to the design of Off-Line and Line-Interactive UPSs, when the AC input source is cut over to the battery source, a delay of 6-8ms in the supply of power to the connected device will occur. The RPS22 power supply treats this delay as an AC dropout condition, and this results in a soft reset. The RPS21 power supplies are not impacted by this condition.
Posted on 06 Oct, 2022, in Uncategorized
How to register an account on Ruckus Support portal
Posted on 05 Oct, 2022, in Uncategorized
Details of LED status on Ruckus Indoor Zone Flex APs
Posted on 04 Oct, 2022, in Uncategorized
FastIron 10.0.00 Stacking Configuration GuideHTML Version: HereApplies to: ICX 7550, 7650, 7850 model switches.
Posted on 04 Oct, 2022, in Uncategorized
FastIron 10.0.00 Software Licensing GuideHTML Version: HereApplies to: ICX 7550, 7650, 7850 model switches.
Posted on 04 Oct, 2022, in Uncategorized
FastIron 10.0.00 Security Configuration GuideHTML Version: HereApplies to: ICX 7550, 7650, 7850 model switches.