Lost POE on two 6450 switches after power outage.Have multiple ICX 6450 switches deployed in a large store in Oregon. Thanks to power outages last night… all the switches came up, but two are not longer providing POE. Tried reloading, hard reboot by power off/onConfirmed llpd & cdp enabledHave no tech support, but do have RMA if needed. Any suggestions?Power Capacity: Total is 740000 mWatts. Current Free is 740000 mWatts.Power Allocations: Requests Honored 0 times Port Admin Oper —Power(mWatts)— PD Type PD Class Pri Fault/ State State Consumed Allocated Error————————————————————————– 1/1/1 On Off 0 0 n/a n/a 3 n/a 1/1/2 On Off 0 0 n/a n/a 3 n/a 1/1/3 On Off 0 0 n/a n/a 3 n/a detail show inline power detailed information <cr>show inline power detailPower Supply Data On stack 1:++++++++++++++++++Power Supply Data:++++++++++++++++++Power Supply #1: Max Curr: 13.7 Amps Voltage: 54.0 Volts Capacity: 740 Wattspower supply 2 is not presentpower supply 3 is not presentPOE Details Info. On Stack 1 :General PoE Data:+++++++++++++++++FirmwareVersion—————-02.1.0 Build 004Cumulative Port State Data:+++++++++++++++++++++++++++#Ports #Ports #Ports #Ports #Ports #Ports #PortsAdmin-On Admin-Off Oper-On Oper-Off Off-Denied Off-No-PD Off-Fault————————————————————————-48 0 0 48 0 0 0Cumulative Port Power Data:+++++++++++++++++++++++++++#Ports #Ports #Ports Power PowerPri: 1 Pri: 2 Pri: 3 Consumption Allocation———————————————–0 0 48 0.0 W 0.0 WAny suggestion would be welcomed!Cheers – James